Sciex PA 800 Plus Pharmaceutical Analysis System- Certified with Warranty

Price

Contact us for price

Location

Pleasanton, CA

orCall (925) 737-0800

Description

The Sciex PA 800 Plus in our stock was manufactured in 2022.

This unit comes certified with a 90-day warranty.

For more information, please contact us.


The PA800 Plus system, utilizing capillary electrophoresis (CE), empowers you to challenge conventional methods and push the limits of analytical capabilities.

Experience consistent, ultra-high-quality separations, day after day, with intuitive, kit-based applications tailored for capillary electrophoresis sodium dodecyl sulfate (CE-SDS), capillary gel electrophoresis (CGE), capillary isoelectric focusing (cIEF), and capillary zone electrophoresis (CZE). These tools enhance your understanding of biotherapeutics and vaccines, enabling you to advance your research with confidence.


The PA800 Plus system supports a wide range of applications, including:

  • Monoclonal antibodies (mAbs) and mAb variants
  • Charge heterogeneity (cIEF)
  • Purity of mAbs and mAb variants (CE-SDS)
  • N-linked glycan analysis
  • In vitro transcribed RNA (IVT RNA)
  • Purity and integrity of mRNA and other IVT RNA (CGE)
  • Purity and size of critical starting material (CGE)
  • Viral vectors
  • Capsid protein purity and ratios (CE-SDS)
  • Virus genome integrity (CGE)
  • Empty-full capsid ratio (CGE and CE-SDS)
  • Purity of critical starting material (CGE)
  • Residual host cell DNA (CGE)
  • Gene editing
  • Purity of guide RNA (CGE)
  • Purity and integrity of Cas9 mRNA (CGE)


Specifications: (From Sciex)

Operating Environment Humidity< 80% (noncondensing) at 15 °C to 30 °C (59 °F to 86 °F)< 60% (noncondensing) at 30 °C to 40 °C (86 °F to 104 °F)Temperature15°C-30°C recommendedOperating SystemWindows 10Sample Temperature Control Range20 °C below the ambient temperature to 60 °C (140 °F)Minimum value: 4 °C (39 °F)Sample Temperature Control Accuracy±2 °C within a range of ±15 °C from the ambient temperature±3 °C outside a range of ±15 °C from the ambient temperatureCapillary Temperature Control Range10 °C below the ambient temperature to 60 °C (140 °F)Minimum setting: 15 °C (59 °F)Capillary Temperature Control Accuracy±1 °C within a range of ±1 °C from the ambient temperature±2 °C outside a range of ±5 °C from the ambient temperaturePressure and Vacuum System RangeInjection: 0.1 psi to 25 psi (pressure) or 0.1 psi to 5.0 psi (vacuum)Rinse: 0.1 psi to 100 psi (pressure) or 0.1 psi to 5.0 psi (vacuum)Pressure and Vacuum System Stability±0.3 psi at 25 psi±1.0 psi at 100 psiPower Requirements100-240 V, 8A, 50-60 HzUV Detector SpecificationsAvailable filters214 nm, Positions for 6 additional filtersFilter bandwidth25 nm nominalUV source30 W pre-aligned deuterium lampPDA (Photodiode Array) Detector SpecificationsBandwidth6 mm minimum (absorbance averaging)Detector type256 element diode arrayScan collection frequency0.5 Hz to 32 HzUV source30 W pre-aligned deuterium lampWavelength accuracy2 nmWavelength range190 nm to 600 nm(Optional) LIF (Laser-Induced Fluorescence) Detector SpecificationsBaseline drift< 0.2 RFU/hrBaseline noise< 0.005 RFU peak to peakDynamic range

 (at a setting of 1,000)> 104Filters488 nm notch filter and 520 nm bandpass filterFilters (optional)Filters for 488 nm laser488 nm notch filter and 520 nm bandpass filterTwo filters are required for user-supplied lasers1 laser filter: to block stray laser light 1 emission filter: to select the wavelength of the emitted light.Filter dimensions requirements• Outer diameter12.7 mm to 0.25 mm (0.5 in. to 0.01 in.)• Thickness0.89 mm (0.35 in.)• Total thickness for multiple filters used in a single channel=< 0.89 mm (0.35 in.)Laser3 mW, 488 nm solid stateRFU range0 RFU to 1,000 RFUSensitivity1 × 1011 M sodium fluorescein with signal-to-noise > 2Wavelength range (for optics)Excitation: 300 nm to 700 nmDetection: 350 nm to 750 nm

Specifications

ManufacturerSciex PA 800 Plus Pharmaceutical Analysis System- Certified with Warranty
ConditionRefurbished
Stock Number14615635